VNISH GLOBAL
Language · English
SHA-256 · VNISH GLOBAL

What 305 TH/s means for an air-cooled S23

A row of a hundred such S23s represents 335.5 kW at the miners before facility cooling. That is a capacity estimate. To measure efficiency, record inlet temperature, power at the miner and average hashrate over the same stable interval.

BITMAIN Antminer S23BITMAIN · S23

Firmware availability

No build for this exact model was verified in the site catalog on 22 November 2026. Check the full model and control board before downloading firmware.

See installation options

Factory rating

ModelAntminer S23
Hashrate305 TH/s
Wall power3355 W
Efficiency11 J/TH

Read the nameplate before choosing firmware

For the air-cooled S23 305T-10, 305 TH/s multiplied by 11 J/TH equals 3355 W. This cross-check catches a misplaced figure in a quotation. An S23 Hyd. has a different cooling system and its own specification. Keep its figures in a separate row.

A field check you can repeat

The same S23 can produce three plausible readings in a shift: instantaneous hashrate in its interface, an average at the pool and power at the distribution unit. Record the start and end of the sample. If the meter also feeds exhaust fans, note their load separately before quoting an efficiency figure for the miner.

Factory specifications and your readings

ComparisonBasisResult
S23 305T-10305 TH/s × 11 J/TH3355 W
10 × S2310 × 3355 W33.55 kW
100 × S23100 × 3355 W335.5 kW

Sources

As of 22 November 2026

BITMAIN · S23 305T-10
BITMAIN · S23 Hyd.